Wayne Jet Pump Water Systems Shallow Well Installation Manual

Browse online or download Installation Manual for Unknown Wayne Jet Pump Water Systems Shallow Well. Wayne Jet Pump Water Systems Shallow Well Installation manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 6
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
JET PUMP
INSTALLATION MANUAL
STEP 5 Install a sanitary well seal onto the top
of the 1 1/4” suction pipe to fit well diameter. Use
1 1/4” tee and a 1 1/4” plug at the top of the well seal
to support suction pipe in the well. Install 1 1/4”
union between well and 1” pressure pipe that will rest
on the well seal to support the pipes and ejector or jet
in well. A 1 1/4” tee or elbow can be used on the top
of the 1 1/4” suction pipe which needs to be slightly
higher than the 1” pressure pipe to make the connec-
tion to the pump housing. Install a compression
coupling on both suction & pressure pipes staggering
them apart from each other. Install 1 1/4” pipe into
the 1 1/4” tap in the pump housing. Install 1” pipe in
to the 1” tap in the pump housing. Join together with
SHALLOW WELL JET PUMPS
STEP 1 Make sure the well is pumped clean and
that sand and grit are absent.
STEP 2 Before installing a shallow well or
centrifugal pump make sure the total suction lift does
not exceed 25 feet.
STEP 3 For convertible jet pumps attach the
ejector to the pump housing, making sure that the
1 1/4” and 1” tapped holes in the ejector match up
with the 1 1/4” and 1” tapped holes in the pump
housing.
STEP 4 Install a 1 1/4” foot valve on the bottom
of the suction pipe, on driven wells, where the well
casing is used as suction pipe, install a 1 1/4”
horizonal line check valve.
Page view 0
1 2 3 4 5 6

Summary of Contents

Page 1 - INSTALLATION MANUAL

JET PUMP INSTALLATION MANUALSTEP 5 Install a sanitary well seal onto the topof the 1 1/4” suction pipe to fit well diameter. Use1 1/4” tee and a 1 1/

Page 2

two unions between the pump and the well. Ifvertical pump is being used, adapt the 1 1/4” and 1”pipes directly into the 1 1/4” and 1” taps in the pum

Page 3 - TROUBLE SHOOTING

STEP 3 Install foot valve to the bottom of the jetor on the bottom of the tail pipe, if the tail pipe isbeing used. Stretch leather cup washer to ope

Page 4 - TROUBLE SHOOTING CONT

CAUSE OF TROUBLE HOW TO CHECK HOW TO CORRECTTROUBLE SHOOTING CONT.A. PUMP WON’T RUN CONT..7. Impeller or seal8. Defective start capacitor9. Motor

Page 5

TROUBLE SHOOTING CONT.D- PUMP WON’T SHUT OFFHOW TO CORRECTHOW TO CHECKCAUSE OF TROUBLE1. Wrong pressure switch setting or settingdrift.2. Defective

Page 6

TROUBLE SHOOTING CONT.E - PUMP OPERATES BUT DELIVERS LITTLE OR NO WATER CONT...10. Low water level in well.11. Plugged ejector.12. Defective or plu

Comments to this Manuals

No comments