Installation of Wiring for Wired
Infrared Safety Sensor
Tools Needed:
Hammer
Uncoil the wires from the infrared safety
sensors and route the wire up the garage
wall across the ceiling and down to the
back of the opener. Tack the wires in place
using staples. Take care to run the wires in
a location where they will not interfere with
the operation of the door and do not staple
through wire.
NOTE: If wires must be lengthened or
spliced into pre wired installation, use wire
nuts or other suitable connectors.
To Opener
Wire to Opener
16
Connecting Wired Infrared Safety
Sensor to Opener
Tools Needed:
Phillips Head
Screwdriver
Connect infrared safety sensors to the
opener as shown. Shorten wires as
necessary and separate wire ends. Strip
about 1/2” of insulation off each wire and
attach wires to the proper terminal screws,
then tighten securely, using phillips head
screwdriver.
One wire has marking on it (numbers, black
stripe, etc). Be sure to observe polarity. Apply
tension to external wires to test for secure
connection. Check that the wires are stapled
in place properly.
P.B.
COM
OBS
Sending Unit
Receiving Unit
Black Strip
Solid
Color
Right Side Of Opener
LED
PRE-OPERATION