EFL33
Operating Instructions and Parts Manual Instructions d‘Utilisation et Manual de Pièces Manual de Instrucciones de Operación y Piezas
20
© 2009 Wayne Water Systems
330102-001 2/09
Effluent
Pump
Operating Instructions and Parts Manual Model EFL33
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Description
An effluent system consists of a pump,
control switch and a basin. The system
is generally controlled by a float switch
with a plug-in plug which accepts the
pump plug and in turn plugs into a 115
volt outlet.
The float switch is a wide angle
differential switch that rises with
the liquid level and turns the pump
on. As the liquid level decreases, the
float lowers and turns the pump
off. This pump is intended for use in
domestic sump or effluent lift stations.
It is suitable for pumping effluent,
wastewater, ground water and other
nonexplosive, noncorrosive liquids with
up to 3/4 inch solids.
Effluent pump will
not pump raw
sewage or any substance exceeding
3/4 inch size.
For parts, product & service information
visit www.waynepumps.com
REMINDER: Keep your dated proof of purchase for warranty purposes!
Attach it to this manual or file it for safekeeping.
Specifications
Power supply requirements .............. 115V, 60 hz
Circuit requirements .......................... 15 amps (min)
Motor duty ......................................... Intermittent
Motor ................................................. 115V, 1 Phase, 1725 RPM
Horsepower ....................................... 1/3
Motor full load .................................. 11 amps
Liquid temperature range ................. 40º F to 120º F
Max. operating position .................... 45º from vertical
Dimensions ......................................... 13-1/2 inch x 11 inch
Intake ................................................. 2 inch
Discharge ............................................ 2 inch NPT female, 3 inch
NPT male
Cut-in level (factory set) .................... 18 inch
Cut-out level (factory set) ................. 10 inch
Differential ......................................... 8 inch
Switch ................................................. 90º wide angle
mechanical tether switch
Power cord ......................................... 16 gauge 3 conductor
w/plug
Construction
Motor body material ............Cold rolled steel
Motor housing ......................Glass reinforced
polypropylene
Volute ....................................Glass reinforced ABS
Impeller .................................Glass reinforced PBT
Seal plate ..............................Cast Iron
Shaft seal ...............................End faced mechanical
Performance
GALLONS PER HOUR AT TOTAL HEAD IN FEET
Model 10 15 200
EFL33 3600 1300 0
Unpacking
Inspect this unit before it is used.
Occasionally, products are damaged
during shipment. If the pump or
components are damaged, return
the unit to the place of purchase for
replacement. Failure to do so could
result in serious injury or death.
Safety Guidelines
This manual contains information
that is very important to know and
understand. This information is
provided for SAFETY and to PREVENT
EQUIPMENT PROBLEMS. To help
recognize this information, observe the
following symbols.
Danger indicates
an imminently
hazardous situation which, if not
avoided, WILL result in death or serious
injury.
Warning indicates
a potentially
hazardous situation which, if not
avoided, COULD result in death or
serious injury.
Caution indicates
a potentially
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
Notice indicates
important
information, that if not followed, may
cause damage to equipment.
General Safety Information
CALIFORNIA PROPOSITION 65
This product or its
power cord contains
chemicals known to the State of
California to cause cancer and birth
defects or other reproductive harm.
Wash hands after handling.
Page view 0
1 2 3 4 5 6 7 8 9 10

Summary of Contents

Page 1 - Effluent

Notes / Notas / NotesEFL33Operating Instructions and Parts Manual • Instructions d‘Utilisation et Manual de Pièces •

Page 2 - Notes / Notas / Notes

Instructions d‘Utilisation et Manual de Pièces10 FrModèle EFL3311 FrEntretien (Suite)2. Enlever le couvercle du bassin et débrancher la tuyauterie de

Page 3 - Model EFL33

2Operating Instructions and Parts Manual Notes / Notas / Notes19EFL33General Safety Information (Continued)GENERAL SA

Page 4 - Modelo EFL33

Manual de Instrucciones de Operación y Piezas18 Sp 3Model EFL33www.waynepumps.comGeneral Safety Information (Continued) The pump motor is equipped

Page 5

4Operating Instructions and Parts ManualModelo EFL3317 Spwww.waynepumps.comMaintenance (Continued)5. Submerge the complete pump in a disinfectant so

Page 6

Manual de Instrucciones de Operación y Piezas16 Sp 5Model EFL33www.waynepumps.com 1 Motor housing 28088-001 1 2 Power cord 31026-001 1 3 #8

Page 7 - Effluente

6Operating Instructions and Parts ManualModelo EFL3315 Spwww.waynepumps.comLimited WarrantyFor one year from the date of purchase, Wayne Water Systems

Page 8 - Efluentes

Manual de Instrucciones de Operación y Piezas14 SpInstructions d‘Utilisation et Manual de Pièces Modèle EFL33Veuillez lire et conserver ces instructi

Page 9

Instructions d‘Utilisation et Manual de Pièces8 FrManual de Instrucciones de Operación y Piezas Modelo EFL33Por favor lea y guarde estas instruccione

Page 10 - Modèle EFL33

Instructions d‘Utilisation et Manual de Pièces12 FrModèle EFL339 FrGénéralités Sur La Sécurité (Suite) Le moteur de la pompe est équipé d’un prote

Comments to this Manuals

No comments